Ac Current (Frequency, Duty Cycle) Measurements - Beta 1760/OHM Manual Del Usuario Y Operador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 202

ac current (FreQuencY, dutY cYcle) measurements

CAUTION: Do not make 20A current measurements for more than 30 seconds. Exceeding 30
seconds may cause damage to the meter and/or the test leads.
1
Insert the black test lead banana plug into the negative com jack.
2
For current measurements up to 5000µA AC, set the function switch
to the µa position and insert the red test lead banana plug into the µa/
ma jack.
3
For current measurements up to 500mA AC, set the function switch to
the mA position and insert the red test lead banana plug into the µa/
ma jack.
4
For current measurements up to 20A AC, set the function switch to the
10a/Hz/% position and insert the red test lead banana plug into the
10A jack.
5
Press the mode button to indicate "ac" on the display.
6
Cut off power from the circuit under test, then open up the circuit at the
point where you wish to measure current.
7
Touch the black test probe tip to the neutral side of the circuit. Touch
the red test probe tip to the "hot" side of the circuit.
8
Apply power to the circuit.
66
 