6.2 AIR INTAKE

The combustion air enters the stove compartment
from the air intake (3) and is drawn into the
combustion chamber through a duct located on the
rear part of the stove.
Make sure that the air intake is located in a way
that it cannot be obstructed by accident.
The UNI 10683 standard forbids the intake of
air for combustion from garages, rooms where
ÀDPPDEOH PDWHULDOV DUH VWRUHG RU ZKHUH WKHUH
LV GDQJHU RI ¿UH
The external air intake hole must not be connected
to the stove by pipes.
If there are other heating units in the room,
the combustion air intakes must ensure the
required volume of air for proper operation of
all devices.
In case in the room where the stove is installed
there are one or more extractors (such as kitchen
aspirators), some troubles to the combustion due
to the lack of comburent air might occur.

6.3 ASSEMBLY DIAGRAM

Assembly must be carried out by qualified
personnel.
1. Seal
2. &RYHULQJ LQ FHUDPLF ¿EUH RU URFN ZRRO ZLWK
DOXPLQLXP IRLO RU ÀXH SLSH ZLWK GRXEOH ZDOO
3. ([WHUQDO DLU LQWDNH EHORZ ¿UHSODFH OHYHO
4. +HDW UHFRYHU\ JULG ¿[ LW RQ WKH KLJKHVW SRLQW
of the cladding.
5. Flame-retardant counter hood and load-
bearing structure
6. 6FUHHQ WKH SDUWV LQ ZRRG ZLWK D ¿UH
retardant material
7. Minimum distance of 1 cm between cladding
and Fireplace
8. ,I WKHUH DUH ÀDPPDEOH PDWHULDOV RU VWUXFWXUHV
RQ WKH EDFN RI WKH ¿UHER[ WKH\ PXVW EH DW D
minimum distance of 20 cm.
The minimum clearance between the stove and
ignitable materials must be 20 cm.
The minimum distance from combustible
materials must be 20 cm.
To ensure correct installation, the smoke pipe
EHWZHHQ WKH ¿UHSODFH DQG ÀXH PXVW EH DLUWLJKW
VHDOLQJ DOO WKH MRLQWV
If the fireplace is installed with a flue that
KDV DOUHDG\ EHHQ XVHG ZLWK RWKHU ¿UHSODFHV
it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
GHSRVLWHG RQ WKH LQVLGH IURP FDWFKLQJ ¿UH
Improper installation may compromise the
safety of the unit. It must be possible for
TXDOL¿HG SHUVRQQHO WR DFFHVV WKH LQVLGH RI WKH
stove when it is not in operation.
48/172
INSTALLATION
1
2
3
7KH FODGGLQJ PXVW EH LQ ¿UHSURRI PDWHULDO DQG
it must not have any removable parts, so that
electrically powered and moving parts are not
accessible by the user.
6.4 PELLETS LOADING
$ GRRU IRU WKH SHOOHWV ORDGLQJ PXVW EH ¿WWHG LQ
the hood and connected to the appliance by
¿WWLQJ DFFHVVRULHV RSWLRQDO )ROORZ FDUHIXOO\ WKH
assembly instructions contained in the package.
We recommend using only original accessories.
The fall of pellets outside the tank could cause
PDOIXQFWLRQLQJ DQG ¿UH LJQLWLRQ