Emergency Release Of The Backrest Or Thigh/Leg Section; Mattress Retainers; Lifting Pole - Invacare Sonata Manual Del Usuario

Ocultar thumbs Ver también para Sonata:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1.
When the back-/footrest has been height adjusted the crank
needs to be locked.
2.
Lock/secure the crank by pushing the white sleeve inwards and
bending the crank by the knuckle.
IMPORTANT!
Twisting or rotating the white sleeve will damage its
internal components and the locking function will
seize to work.
– Only push the white sleeve inwards without
twisting.
3.
The handle always has to be in the folded position, when
the crank is not used.
4.5 Emergency release of the backrest or
thigh/leg section
An emergency release of the backrest or thigh/leg section could be
necessary in the case of power- or motor failure.
CAUTION!
Risk of injury
– A minimum of two persons are required to release
a mattress section.
– An emergency release of the height adjustment is
NOT possible.
– Remove the plug from the mains socket before
emergency release of the mattress support.
1.
Both persons hold the mattress section.
2.
One of them pulls out the cotter pin (from the motor in
question).
3.
Both persons slowly lower the mattress section until it is
completely down.
1574228-D

4.6 Mattress retainers

WARNING!
Risk of injury
If the mattress retainers are removed the mattress
will not follow the movement, when adjusting the
head-/legsections. The mattress can slip sideways and
cause the user to fall out of the bed or get trapped in
the bed.
– Always use mattress retainers and be careful to put
them back after any adjustments.

4.7 Lifting pole

WARNING!
Risk of injury
If the lifting pole is used while the handle has been turned
away from the bed, the bed can tip when the handle is
used.
– Position the lifting pole in such a way that the handle
extends inwards across the bed.
Mounting
1.
Remove the plug from the lifting pole tube at the head end of the
bed where the lifting pole is to be placed.
2.
Insert the lifting pole into the lifting pole tube and fix with the
thumb screw.
Adjusting the height of the lifting pole handle
1.
Loosen the cord.
2.
The lifting handle can now be adjusted to the desired height.
3.
Press the cord together and check that the cord is locked in the
cord lock by pulling the handle.
The distance between the lifting pole and the mattress
Minimum (at 16 cm mattress)
Maximum (at 10 cm mattress)
Operating the bed
36-59 cm
42-65 cm
11
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

1574228-d

Tabla de contenido