Novellini UNA Manual De Instalación, Uso Y Mantenimiento página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
complies with current health and safety standards. All items and components are factory tested
according to reference standards and in-house quality procedures. To ensure that the bath continues
to be safe even after installation and throughout its useful life, check the following:
1) The electrical system to which the bath is to be connected must conform with current regulations
and standards. Remember that the system must be properly earthed.
2) All electrical fittings (power outlets, switches, etc) must be at least 60 cm from the bath or at a
height of 225 cm.
3) The power supply line must be suitable for the power requirement of the bath (see technical
specifications, page 27).
4) The point where the bath is connected to the electrical system must be suitably protected
against splashing water (degree of protection IP55 or greater).
5) The whirlpool system must be fitted with a 30 mA switched circuit breaker with a minimum
contact opening of 3 mm.
6) The bath frame has an earth terminal that must be properly connected to the earthing system
of the supply circuit,
7) The whirlpool baths is provided with electrical connection of the type Y, if the power cord is
damaged, it must be replaced by the manufacturer or by its technical assistance service or in
any case a person with similar qualification, so as to prevent any risk.
(refer to illustrations on page 34).
equipotentiality
-7-
ENGLISH
Tabla de contenido
loading

Este manual también es adecuado para:

VenusVogueCalypsoCalos 2.0

Tabla de contenido