DMX Protocol
Channel
Function
CH1
Pan scan
CH2
Tilt scan
CH3
Pan / tilt speed
CH4
Dimmer
CH5
Strobe
CH6
Frost
CH7
color
CH8
Gobo
CH9
Prism
CH10
Prism rotation
CH11
reset
CH12
Lamp control
CH13
Laser gobo
CH14
Laser gobo speed
CH15
Laser effect 1
CH16
Laser effect 2
BEAMER STREAM - 5R BEAM AND LASER SIMULATOR
ENGLISH VERSION
1-50 lamp on 51-240 strobe from slow to fast 241-255 lamp on
0-127 no applicable
0-106 clockwise rotate from slow to fast 107-180 anticlockwise from slow to fast 181-255
prism rotate and shake from slow to fast
0-254 not applicable 255 stays for 3 seconds then reset
0-99 not applicable 100-105 lamp off, last 3 seconds, 106-199 no applicable 200-205 lamp
on, last 3 seconds, 206-255 no applicable
0-10 not applicable 11-239 laser gobo 240-255 shut up laser function
0-255 gobo running from fast to slow
0-127 clockwise running from slow to fast
128-255 anti-clockwise running from slow to fast
0-127 clockwise running from slow to fast
128-255 anti-clockwise running from slow to fast
Description
0-255 0°-540°
0-255 0°-265°
0-255 from fast to slow
0-255 from dark to bright
0-255 from strong to impotent
0-255 from color to color
0-255 from gobo to gobo
128-255 rotate prism
p. 9