(53)
COMPRESSOR I/O (INPUT/OUTPUT)
These 1/4" stereo (TRS) jacks allow the internal compressors for each SUB group to be
patched to an input channel or to an external device. The tip carries the input (return) signal
to the compressor and the ring carries the output (send).
(54)
SUB OUT
These 1/4" (TRS) unbalanced outputs provide signal from the SUB groups.
(55)
AUX 1 - 6 OUT (UNBALANCED)
These 1/4" (TS) jacks provide signal from the AUX buses.
(56)
AUX 1 - 4 OUT (BALANCED)
These XLR connectors are provided on AUX 1–4 and provide output from those buses.
These can be used simultaneously with the unbalanced jacks (55), but both levels will be
determined by the AUX SEND LEVEL (21).
POWER
(57)
REMOVABLE POWER CORD
This receptacle is for the IEC line cord (included) that provides AC power to the unit. Connect
the line cord to this connector and to a properly grounded AC supply. Damage to the
equipment may occur if an improper line voltage is used (see voltage marking on unit). Never
remove or cut the ground pin of the line cord plug. The console is supplied with a properly
rated line cord. If lost or damaged, replace this cord with one of the proper rating.
NOTE: FOR UK ONLY
If the colors of the wires in the mains lead of this unit do not correspond with the colored
markings identifying terminals in your plug, proceed as follows: (1) The wire that is colored
green and yellow must be connected to the terminal marked by the letter E, or by the earth
symbol, or colored green or green and yellow. (2) The wire that is colored blue must be
connected to the terminal that is marked with the letter N, or colored black. (3) The wire
that is colored brown must be connected to the terminal that is marked with the letter L
or colored red.
(58)
POWER SWITCH
Place this switch in the "|" position to apply power to the RQ 4300. Return it to the "O"
position to turn the unit off. It is recommended that the unit be turned off while patching
and/or applying power to external equipment to be used in conjunction with the RQ 4300.
The POWER LED (48) will illuminate when power has been applied and the unit is on.
13