5. WIRING

- Switch the power supply off.
- Connect the io On/Off Lighting receiver as
shown in the table below and the illustration :
- Mains 230V/50 Hz (A)
- Power supply (AC/DC) (B)
- Control voltage (1-10V) (C)
Blue
Brown
A
Green/Yellow
Cable length

6. SET-UP

This guide describes set-up using only a Situo io type Somfy io local control point. To perform
set-up using a different io control point, refer to the corresponding instructions.
Light on
Programming a Somfy io local control point
Only one blank receiver must be powered at a time.
- Switch on the power supply.
- Press the Up/Down buttons on the Somfy io local control
point simultaneously and follow procedure "a" or "b" de-
pending on how the light reacts:
a) The light comes on then goes out.
%ULHÀ\ SUHVV WKH 352* EXWWRQ RQ WKH 6RPI\ LR ORFDO
control point: the light comes on then goes out again to
indicate that the Somfy io local control point has been
programmed into the io On/Off Lighting Receiver.
Go to section 7 "Use".
b) The light does not come on.
Press the Up button.
c) If the light comes on:
The Somfy io control point has been programmed.
Go to section 7 "Use".
d) If the light does not come on:
- Check the status of the light/LED/converter and try
again.
 *R WR 6HFWLRQ  ³5HVWRULQJ WKH RULJLQDO FRQ¿JXUDWLRQ´
© 2015 Somfy SAS. All rights reserved. 01/2015
Neutral
Blue
Live
Brown
B
Earth
Green/Yellow
30 cm
Cable length
«my» light
Light off
position
B
50 cm
A
230V ~
50Hz
30 cm
Neutral
Blue
Live
Brown
C
Earth
Cable length
50 cm
50 cm
Dim +
Dim -
50 cm
Feedback
ON
a
b
c
+
-
C
d
7
Tabla de contenido
loading

Tabla de contenido