4 Technical data
Dust extractor CT 26 E, CT 36 E, CT 48 E
Power consumption (dust extractor only)
Total connected load
Max. rating of connected Power Tool
Volume flow (air), turbine
Vacuum, turbine
Filter surface
Suction hose (diameter x length)
Protection type
Sound pressure level as per IEC 60704-2-1
Container capacity
Dimensions L x W x H
Weight
5 Functional description
The pictures for the functional description are
on a fold-out page at the beginning of the in
struction manual. When reading of the manual
you can fold out this page for having always an
overview of the machine.
Accessories shown or described are sometimes
not included in the scope of delivery.
[1] ) 8.3 A (1000 W) is the medium value for different operation conditions, a maximum power consumption of 10 A (1200 W) is possible.
[2] ) When the suction power adjuster [1-7] is adjusted to the lowest suction power (see page
connected power tool can be 9.1 Amps.
8
safety equipment, such as dust masks that are
specially designed to filter out microscopic par
ticles. Wash hands after handling.
TO REDUCE THE RISK OF INJURY, USER
MUST READ INSTRUCTION MANUAL.
max.
max.
max.
CT 26 E
CT 36 E
CT 48 E
CT 26 E
630 x 365 x 540 mm (24.8" x 14.4" x 21.3")
CT 36 E
630 x 365 x 596 mm (24.8" x 14.4" x 23.5")
CT 48 E
CT 26 E
CT 36 E
CT 48 E
[1-1]
Intake opening
[1-2]
Module slot
[1-3]
Appliance socket
[1-4]
Hose store
[1-5]
Handle
[1-6]
SysDoc
[1-7]
Suction power adjuster
WARNING
2.9 - 8.3 A (350 - 1000 W)
12 A (1440 W)
234 m³/h (8264 cu.ft./h)
6318 cm² (979.3 sq.in.)
27 mm x 3.5 m (1-1/16" x 11.5')
48 l (12.7 gal.)
715 x 392 x 680 mm
(28.1" x 15.4" x 26.8")
13 kg (28.7 lbs)
14.4 kg (31.8 lbs)
16.3 kg (35.9 lbs)
Page
10, chapter
8
-
8.4
) the maximal rating of a
English
.)
[1]
3.7 A
.)
[2]
24000 Pa
IP X4
71 dB(A)
26 l (6.9 gal.)
36 l (9.5 gal.)