The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
120º
7m
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor's detection
area. They may cause sensor malfunction.
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
Set
COOL/DRY
temperature
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.

Operation conditions

Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
COOL
• Based on area activeness horizontal airfl ow direction will adjust either fi x
at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit
location, movement speed, temperature range, etc.
Indoor
DBT
Max.
32
Min.
16
+1 °C
Outdoor
WBT
DBT
23
43
11
16
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
WBT
26
11
19