3. Make Electrical Connections

NOTE: The product model number is printed on a label on the blower side of the bath. This label also
identifies the electrical rating of the product. All baths come equipped with a wiring junction box and
are designed to operate between 220 V and 240 V at either 50 Hz or 60 Hz.
WARNING: Risk of electric shock. Disconnect the power before performing the following
procedures.
WARNING: Risk of electric shock. Connect the blower to a properly grounded Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This will provide additional
protection against line-to-ground shock hazard. A 220-240 V, 20 A, 50/60 Hz dedicated circuit is
required.
IMPORTANT! The load neutral is not used. There should be no connection to the load neutral terminal
on the Ground-Fault Circuit-Interrupter (GFCI) breaker. The green wire with the yellow stripe is the
equipment ground and needs to be connected to the neutral bus in the main circuit breaker box.
IMPORTANT! Some equipment and installations vary. Refer to "Alternate Wiring Connection" as shown.
NOTE: The wiring harness includes an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
1204120-2-D
Two-Pole Circuit
Breaker with GFCI
*L2
240 V
*L1
No Connection
(Load Neutral)
Provide suitable
strain relief.
Field Wiring
(From Junction Box
to GFCI Breaker)
Control
Power Supply
Bond in accordance
Junction
Box
with local codes.
8
Typical Wiring Connection
Ground
(Green)
Ground
White
(Green with
(Neutral)
Yellow Stripes)
From Heated
Surface
Blue
From Control
(L1)
Black (L1)
Wire
Connector
Alternate Wiring Connection
White or
Ground
Wire
Blue
(Green with
Connector
(Neutral)
Yellow Stripes)
From Heated
Blue
Surface
(L1)
From Control
Brown (L2)
Black or Brown
Brown (L2)