Bond in accordance
with applicable codes.
Heater
6. Make Electrical Connections
WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the pump to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI). This will provide additional protection
against line-to-ground shock hazard. A 120 V, 15 A dedicated circuit is required.
WARNING: Risk of electrical shock. Make sure the power has been disconnected before performing
the following procedures.
Locate and secure the supplied junction box a minimum of 1-1/2" (3.8 cm) above the subfloor.
The whirlpool controls and system have been prewired at the factory. A licensed electrician should
make a routine service connection to the junction box.
Connect service to the junction box. The 60 Hz model junction box contains black and white wires
and a ground lug.
A 120 V, 15 A dedicated circuit is required. Provide a Class A Ground-Fault Circuit-Interrupter
(GFCI).
Provide a separate equipment grounding conductor for the inside ground or ground lug. The
conductor must not be connected to any current-carrying conductor.
Bond in accordance with national and local codes.
7. Test Run the Whirlpool
Check all electrical connections, and make sure the electrical power to the whirlpool and heater (if
equipped) is on.
Make sure all union connections to the pump and heater are securely hand tightened.
1012844-2-C
Junction Box
Electrician to provide
suitable strain relief.
8
Ground
Neutral
(White)
Neutral
A licensed electrician should make
the connections to the junction box
for both the pump and heater.
Wire
Connectors
From Pump
Line
(Black)
Line
Kohler Co.