5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams on page 18.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm
in the open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure
multi pole disconnection from the power supply, with a contact opening of 3 mm.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
1-2
+24 V
power supply output for auxiliary devices 200mA
3-4
22 V ~ transformer power supply input
24 V
battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity
5-6
indications).
7-8
Operator 1 output
9
Connection of motors metallic parts
10-11
Operator 2 output (if present)
12-13
24 V
max 15 W output for open gate fix/flashing warning light (if P052=0/1) or courtesy light (if P052>1)
Electric-lock output max 1 art. 110 (if P062=0), 24V
14 (-)
14-15
electro-brake output for reversible motors (if P062=3)
15 (+)
16-17
24 V
Flashing light output max 15W art. Lumy/24A/S
18 - N.C.
Input 6 STOP . In case of intervention, it stops the movement of both motors during any
18-19
operation. If unused, short circuit.
19 - Com
Input 5 PHOTO 2. When enabled (see parameter P051 in the table), activation of
20 - N.C.
20-21
PHOTO 2 provokes: an inversion of direction (during closing), the arrest of the mo-
21 - Com
vement (during opening), prevent the start (gate closed). If unused, short circuit.
Input 4 PHOTO 1. When enabled (see parameter P050 in the table), activation of
22 - N.C.
22-23
PHOTO 1 provokes: an inversion of direction (during closing), the arrest of the mo-
vement (during opening), prevent the start (gate closed). If unused, short circuit.
23 - Com
24 - N.C.
Input 3 SAFETY. If activated, it causes the inversion. See P055 and P056 on the para-
24-25
meters table. If unused, short circuit.
25 - Com
26 - N.O.
26-27
Input 2 PED. If activated, it opens motor nr. 1 only.
27 - Com
28 - N.O.
Input 1 START. In case of intervention it provokes: the operator opening or closing. It
28-29
may operate as "inversion" mode (P49=0) or "step by step" mode (P49=1).
29 - Com
30
Aerial signal input
31
Ground aerial input
32-33
DEA_NET net input (unused at the moment)
CON 1
230 V ~ ±10% (50/60 Hz) power supply input
CON 2
Connection of encoder to operator 2 (1-2-3)
CON 3
Connection of power supply to operator 2 + ground (4-5-6)
Encoder selection Jumper:
J5
J9
•A position = operators with encoder (remind to set P029=0)
B
A
B
A
•B position = operators without encoder (remind to set P029=1)
Table 1 "terminal board connections"
.
2
output max 5W configurable (if P062≠0) or
17