Tabla de contenido
Idiomas disponibles

Idiomas disponibles

XX(second)
 Angle Display Format: XXX.XX(pan)/XXX.XX(tilt)
 IR Display: ☀ means the IR is turned on.

4 OSD Menu

4.1 System

<MAIN MENU>
<SYSTEM>
<DOME>
<CAMERA>
<IR>
<DISPLAY>
<TIME>
<LANGUAGE>
<RESET>
EXIT
<SYSTEM>
PROTOCOL
PELCO-D/P
COMM
DOME ID
MODULE
VERSION
MAX SPEED
<COMM SET>
<PASSWORD SET>
EXIT
CANCEL
<COMM SET>
DEVICE ID
CHECK ID
TARGET ID
BAUDE RATE
SAVE
EXIT
20
<SYSTEM>
 PROTOCOL: Displays the protocol of the dome.
 COMM: represents the communication Information; 2400 is
the baud rate, which can be changed via the DIP switches or
2400.N.8.1
software the available baud rates are: 1200, 2400, 4800 and
001
9600. "N.8.1" represents the Check bit,
bit.
300
 DOME ID: This is the address number of the dome. The
range is 000-255.
 MODULE: Displays the brand and model of the installed
camera module.
 VERSION: Displays the current operating system.
 <COMM SET>
 DEVICE ID: Used to distinguish this dome from the ID of
other domes.
 CHECK ID: Enter the device ID above into this field to
enable address changes for just this camera.
 TARGET ID: Enter the new address you wish to assign to
this camera. It will be effective immediately after it is changed.
means the IR output power.
Data bit and Start
Tabla de contenido
loading

Tabla de contenido