12. Maintenance and Servicing

Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the shower head must be maintained and serviced at
regular intervals.
Use suitable cleaning agents that are not harmful to the shower head in a proper
manner and rinse with water after use. High-pressure cleaners must not be used for
cleaning.

13. Replacing the Flow Rate Regulator

13.1 Loosen the grub screw using a hollow hexagon wrench.
13.2 Pull the shower head from the connection spigot.
13.3 Use a face spanner to loosen and remove the retaining ring.
13.4 Remove the following parts from the shower head.
a: Seal
b: Ball
13.5 Replace the flow rate regulator. Note details provided in the table.
13.6 Insert the following parts into the shower head.
a: Seal
b: Ball
13.7 Use a face spanner to tighten the retaining ring (a).
13.8 Slide the shower head onto the connection spigot.
13.9 Screw-in the grub screw using a hollow hexagon wrench.

14. Fault Correction

Fault
Spray pattern is
irregular
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
6
Cause
– Shower head is dirty
– Flow rate controller faulty
– Shower head is dirty
– Flow rate controller faulty
Remedy
➯ Clean it
➯ Replace it
➯ Clean it
➯ Replace it