Type-Identical Marking; Use; Preconditions For Use - Dräger FPS 7000 Instrucciones De Uso

Ocultar thumbs Ver también para FPS 7000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48

Use

2.6

Type-identical marking

The facepieces are marked differently:
Connector
RA, PE, ESA, P
EPDM or Si,
Mask body
EN 136:1998 CL.3+
CExxxx (notified body in Europe)
Size of mask body
S (small), M (medium), L (large)
Size of inner mask
1 (small), 2 (medium), 3 (large)
PC or APEC, F (fire brigade), according to
EN 166
A (ballistic protection class 190 m/s)
T (ballistic protection at extreme
temperatures,
Visor
tested at –30...+60 °C with 190 m/s)
PCas or APECas (coated with scratch-
resistant material on both sides)
PCaf (coated with scratch-resistant material
on the outside, with anti-fog material on the
inside)
Elastic straps
EPDM, CR or Si, M/L or S
Mask/helmet adapter H61 (S-fix) or H62 (Q-fix)
22
3
Use
3.1

Preconditions for use

The mask/helmet combination needs to be carefully adapted to the
equipment wearer (correct mask size, fastening plate settings and
internal helmet components) due to the rigid structure.
The following preconditions have to be observed when using the full
face masks with a respiratory filter or a powered air purifying
respirator:
The ambient conditions (particularly the types and concentrations
of contaminants) must be known. Use corresponding respiratory
filters. Only use SCBAs or air line breathing apparatus in cases
where the contaminant is unknown.
Only use filtering devices if the air does not directly endanger the
health or life of the user.
It must be ensured that the ambient atmosphere cannot change to
the worse.
Do not use filtering devices if there is suspicion of contaminants
with low warning properties (low-odour, tasteless, no irritation of
eyes and airways). A decreasing protective effect of the filtering
device cannot be determined in this case.
Do not use filtering devices for entering unventilated tanks, mines,
canals, etc.
Do not use filtering devices in oxygen-enriched atmospheres.
The oxygen content of the ambient air must not drop below the
following limit values:
at least 17 Vol% oxygen in all European countries except the
Netherlands, Belgium and the UK
at least 19 Vol% oxygen in the Netherlands, Belgium, the UK,
Australia and New Zealand
In other countries, observe the applicable national regulations.
(approved by Dekra Exam)
Dräger FPS 7000
Tabla de contenido
loading

Este manual también es adecuado para:

Fps 7000 s-fixFps 7000 q-fix

Tabla de contenido