Troubleshooting - Iberspa 25414 Manual De Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Compact Equipment Manual for residential fitted Spas

7. TROUBLESHOOTING

PROBLEMS
FILTERING
Low water flow during filtering.
MASSAGE
The massage pump does not turn
on.
Low air flow in the jets.
Water leaks out of the Venturi.
It does not work.
HYDROMASSAGE
Low air flow.
The air pump does not turn on.
It does not work
HEAT EXCHANGER
The thermostat does not display
the temperature correctly.
The water does not heat up.
It does not work.
CAUSES
Blocked filter
Signal transmission tube is disconnected.
Air bulb of the pushbutton is
disconnected.
Venturis are closed and blocked.
Jets closed.
Blown fuse. (4. Operation)
Motor brushes are worn.
Signal transmission tube is disconnected.
Air bulb of pushbutton is worn.
Blown fuse (4. Operation)
Temperature probe is not in position.
Faulty probe.
Heat exchanger does not work.
Blow fuse (4. Operation)
15
English
SOLUTIONS
Wash the filter.
Connect the tube.
Change the bulb.
Open venturis.
Remove blockage
Open jets.
Reset pump
Change brushes.
Connect tube.
Change bulb.
Reset pump
Place the probe in its correct
position.
Change probe.
Heat exchanger switch is in
the off position
Reset the safety thermostat
Reset the pump
.