Compact Equipment Manual for residential fitted Spas
2. INSTALLATION
2.1. POSITIONING THE COMPACT EQUIPMENT
Place the equipment in a room near the Spa. The maximum distance between the equipment and the
Spa is 7 metres, and the minimum distance is 2 metres.
measurements, please consult your supplier.
ATTENTION – The maximum distance is the length of the connection piping between the
equipment and the Spa.
The compact equipment should be below the level of the Spa, thereby avoiding the need to prime the
pumps. The maximum slant is 1 metre above the Spa and 2 metres below.
Do not position the equipment anywhere where water could leak into the electrical equipment
compartment.
It should be easily accessible for maintenance work.
2.2 ASSEMBLY OF THE EQUIPMENT
The following type of piping should be used for the connection:
•
Filtering circuit:
•
Massage circuit (jets):
•
Air massage circuit:
*On standard distance (maximums 7 m) and without losing power charge.
Follow the diagrams and assembly instructions given below for each circuit.
In any event, the installation of bends and piping should be reduced to a minimum in order to reduce
the load loss of the installation.
Always use plastic accessories, gasket and teflon tape for the selector valve connections. Never use
steel accessories or piping as they could seriously damage the plastic components.
PN 10 diameter 50 mm*
PN 10 diameter 50 mm*
PN 10 diameter 50 mm*
3
If it is not possible to respect these
English
.