GPL5 manual-3_REV3:Bosch 10/26/11 6:48 PM Page 5
must be repaired.
Store idle tool out of the reach of children
and do not allow persons unfamiliar with
the tool or these instructions to operate
the tool. Tools are dangerous in the hands
of untrained users.
Maintain tools. Check for misalignment or
binding of moving parts, breakage of
parts and any other condition that may
affect the operation. If damaged, tool
must be repaired by the authorized Bosch
service center before further use. Many
accidents are caused by poorly maintained
tools.
Use the tool, accessories, etc., in
accordance with these instructions and in
the manner intended for the particular
type of tool, taking into account the
This tool projects plumb and horizontal points and is intended for accurate transfer and
alignment of plumb, level, graded and 90-degree points
Inserting/Replacing the Battery
Alkaline batteries are recommended for
the tool.
To open the battery compartment 3, turn the
latch 2 in clockwise direction to position
and pull off the battery lid. Insert the
batteries provided.
When inserting, pay attention to the correct
polarity according to the representation on
the inside of the battery compartment.
Position the battery lid to the bottom of the
housing and then push it upward. To lock the
battery lid, turn the latch 2 in
The numbering of the product features shown
refers to the illustration of the tool on the
graphic page.
1 Exit opening for laser beam
2 Latch of battery lid
3 Battery lid
4 On/Off switch
5 Laser warning label
6 Tripod mount 5/8-11
7 Serial number
8 Multi-Purpose Attachment
9 Locking screw for Multi-Purpose
Attachment
working conditions and the work to be
performed. Use of the tool for operations
different from those intended could result in a
hazardous situation.
Have your tool serviced by a qualified
repair person using only identical
replacement parts. This will ensure that the
safety of the tool is maintained.
Develop a periodic maintenance schedule
for tool. When cleaning a tool be careful
not to disassemble any portion of the tool
since internal wires may be misplaced or
pinched or may be improperly mounted.
Certain cleaning agents such as gasoline,
carbon tetrachloride, ammonia, etc. may
damage plastic parts.
Intended Use
Preparation
counterclockwise direction to the
When the laser beams flash slowly during
operation,the batteries are low. When the
flashing begins, the tool can be operated for
approx. 8 h.
Always replace all batteries at the same time.
Only use batteries from one brand and with
the identical capacity.
• Remove the batteries from the
tool when not using it for extended
periods. When storing for extended
periods, the batteries can corrode and
discharge themselves.
Features
10 Screw holes of Multi-Purpose Attachment
11 Opening for strap attachment
12 Magnets
13 1/4-20 tripod mount on Multi-Purpose
Attachment
14 5/8-11 tripod mount on Multi-Purpose
Attachment
15 Measurement plate with stand*
16 Protective Case "not shown"
17 Laser viewing glasses
18 Tripod*
*The accessories illustrated or described are
not included as standard delivery.
-5-
Service
position.