AKM2G Instructions | 1 English
1.4 Technical Description
1.4.1 General technical data
Ambient temperature
(at rated values)
Permissible humidity
(at rated values)
Power derating
(currents and
torques)
Ball-bearing life
Technical data for every motor type can be found in chapter "Technical Data" from
Technical
1.4.2 Standard features
1.4.2.1 Style
The basic style for the AKM2G motors is style IM B5
according to EN 60034-7.
1.4.2.2 Flange
IEC flange accuracy according to DIN 42955. Tolerances of shaft extension run-out and of mounting
flanges for rotating electrical machines.
Code Flange
A
IEC with accuracy N, fit AKM2G2-7: j6
1.4.2.3 Protection class
Per EN 60529.
Standard Motor
AKM2G2-AKM2G7
AKM2G2-AKM2G7
1.4.2.4 Insulation material class
The motors are supplied with insulation material class F according to IEC 60085 (UL1446 class F).
16
Kollmorgen | kdn.kollmorgen.com | August 2020
5...+40°C for site altitude up to 1000m amsl
It is vital to consult our applications department for ambient temperatures
above 40°C and encapsulated mounting of the motors.
95% rel. humidity, no condensation
1%/K in range 40°C...50°C up to 1000m amsl
for site altitude above 1000m amsl and 40°C
6% up to 2000m amsl
17% up to 3000m amsl
30% up to 4000m amsl
55% up to 5000m amsl
No derating for site altitudes above 1000m amsl with temperature
reduction of 10K / 1000m
≥ 20.000 operating hours
Data.
Connector Option
C, D, G, H, J, Y
C, D, G, H, J, Y
Shaft Seal
Protection class
without
with
IP54
IP65