USER U/I subme-
6.
nu (user settings
for current and
voltage)
(continued)
7.
8.
9.
10. Press Start/Stop button to exit
Set max. charging time until float charging (setting range: 10 min - 24 h)
-
Press Start/Stop button
-
Display flashes. Adjust time in 10 min intervals
-
Press Start/Stop button to confirm setting
Set floating charge voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Display flashes. Adjust floating charge voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Set external power supply voltage (setting range: 12.0 - 15.5 V)
-
Press Start/Stop button
-
Adjust external power supply voltage in 0.1 V steps
-
Press Start/Stop button to confirm setting
Set maximum external power supply (Setting range: see Technical Data)
-
Press Start/Stop button
-
Adjust external power supply in 0.5 A steps
-
Press Start/Stop button to confirm setting