REARMING
MK5 AUTOMATIC
Step 1
Unscrew the automatic cartridge by turning it anti-clockwise
and discard it in an environmentally friendly manner. Replace
it with the new cartridge which will have the green indicator
in place, by turning it clockwise. Tighten up hand tight .
Step 2
Remove the pierced CO² cylinder by turning it anti-clockwise
and discard it in an environmentally friendly manner.
Step 3
If the unit has been manually activated, push the lever back
into its slot until it clicks into position and clip the new manual
indicator in place.
Step 4
Ensure the black CO² cylinder seal is fitted correctly.
Step 5
Ensure the CO² Cylinder cap has not been pierced
and then screw it clockwise into the UML-5
inflator. Tighten up, hand tight.
• Do not detach the inflator from the lifejacket.
• Before commencing the rearming procedure
ensure you have the correct re-arming kit with
the correct size CO² cylinder and that the
lifejacket is dry.
• Keep away from fluids.
• Ensure the automatic cartridge in the re-arming
kit is within its Replace By Date
14