Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
UML MK5 INFLATION SYSTEM
The MK5 Automatic lifejacket inflator is a robust, compact unit used in both leisure and commer-
cial activities. This unit supports both manual and automatic inflation activation, with the dual
status indication system confirming that the inflator has been activated.
The indication on the standard MK5 Automatic inflator allows the user to establish if the system
has been fired. The standard MK5 Automatic inflator does not indicate if a pierced CO2 cylinder
is accidentally refitted to the inflator during the servicing procedure. The CO2 cylinder must be
checked each time you don your lifejacket to ensure it is not pierced and it is tightly screwed
in by hand. In addition the cartridge must be checked to ensure it has not passed the replace
by date, it is also fully screwed on tightly by hand and water is not restricted from entering the
system.
There are 2 forms of indication :
1.
The Automatic Indicator
2.
The Manual Indicator
Both indicators must be green, the Automatic capsule must be fully screwed on hand tight and
must be within the printed Replace By Date and a fully screwed in hand tight, full CO2 Cylinder
for correct operation.
The Automatic Indicator is positioned on the base of the Automatic Firing Mechanism.
GREEN
indicates OK, and
The Manual Indicator is positioned on the side of the firing head.
GREEN
indicates OK, and
These should checked each time the lifejacket is worn.
If either or both of these indicators are red or missing please refer to the Re-arming tab above.
RED
indicates STOP/NOT USABLE.
RED
indicates STOP/NOT USABLE.

INFLATION SYSTEM

7
Tabla de contenido
loading

Este manual también es adecuado para:

Classic 190Active 190Active 300Dynamic 190Dynamic 300

Tabla de contenido