Instructions for use CLIC Absorber Free / Infinity ID CLIC Absorber Free / CLIC Adapter enUS English US
Trademarks
Trademarks owned by Dräger
Trademark
®
Drägersorb
The following web page provides a list of the countries in which the
trademarks are registered: www.draeger.com/trademarks
Trademarks owned by third-party manufacturers
Trademark
Trademark owner
®
Neodisher
Dr. Weigert
®
Gigasept
Schülke & Mayr
Definitions
WARNING
A WARNING statement provides important information
about a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
A CAUTION statement provides important information about a
potentially hazardous situation which, if not avoided, may result
in minor or moderate injury to the user or patient or in damage
to the medical device or other property.
NOTE
A NOTE provides additional information intended to avoid
inconvenience during operation.
Definition of target groups
For this product, users, service personnel, and experts are defined
as target groups.
These target groups must have received instruction in the use of
the product and must have the necessary training and knowledge
to use, install, reprocess, maintain, or repair the product.
The product must be used, installed, reprocessed, maintained, or
repaired exclusively by defined target groups.
Users
Users are persons who use the product in accordance with its
intended use.
Service personnel
Service personnel are persons who are responsible for the
maintenance of the product.
Service personnel must be trained in the maintenance of medical
devices and install, reprocess, and maintain the product.
Experts
Experts are persons who perform repair or complex maintenance
work on the product.
Experts must have the necessary knowledge and experience with
complex maintenance work on the product.
14
Symbols
REF
Rx only.
CAUTION: Federal law restricts this device to sale by or on the
order of a physician.
For your safety and that of your patients
WARNING
Risk of incorrect operation and of incorrect use
Any use of the medical device requires full understanding
and strict observation of all sections of these instructions
for use. The medical device must only be used for the
purpose specified under "Intended use".
Strictly observe all WARNING and CAUTION statements
throughout these instructions for use and all statements on
medical device labels. Failure to observe these safety
information statements constitutes a use of the medical
device that is inconsistent with its intended use.
General safety notes
WARNING
Risk of patient injury
The medical device must be checked prior to each use.
When parts are damaged or incomplete, the medical device
must be replaced.
WARNING
Risk of patient injury
The disposable CO
conjunction with inspiratory CO
WARNING
No modification of the medical device is allowed. Modifica-
tion may damage or impair the proper functioning of the de-
vice which may lead to patient injury.
WARNING
Observe the instructions for use of the respective
anesthesia workstation.
The disposable CO
the functionality of the Dräger anesthesia workstation and CLIC
adapter. Correct functioning of the equipment cannot be
guaranteed if other disposable CO
Instructions for use CLIC Absorber Free / Infinity ID CLIC Absorber Free / CLIC Adapter
Keep away from sunlight
Consult instructions for
use
Storage temperature
limitation
Relative humidity
Part number
LOT
Manufacturer
Quantity
Diameter of soda lime
CAS 2390-
pellets
59-2
absorber must only be used in
2
2
absorber has been specially matched with
2
Do not reuse
Bypass
Atmospheric pressure
Use by
Lot number
Date of manufacture
Color change
Color indicator
monitoring.
absorbers are used.
2