4. AUTO MODE SETTING
4.1
T4AUTOCMIN
The minimum operation ambient temperature for cooling
4.2
T4AUTOHMAX
The maximum operation ambient temperature for heating
5. TEMP. TYPE SETTING
WATER FLOW
The selection of whether the water temp. will be displayed
5.1
TEMP.
on the home page
The selection of whether the room temp. will be displayed
5.2
ROOM TEMP.
on the home page
6. ROOM THERMOSTAT
ROOM
6.1
The selection of whether the room thermostat is avalaible
THERMOSTAT
The selection for whether the mode setting is avalaible
6.2
MODE SETTING
by thermostat
DUAL ROOM
The selection for whether the dual room thermostat
6.3
THERMOSTAT
is avalaible
7. OTHER HEATING SOURCE
7.1
BACKUP HEATER
The selection for whether the inner hydrobox heater is avalaible
The selection for whether the backup heater will be used
7.1.1
HEAT MODE
in space heating mode
The selection for whether the backup heater will be used
7.1.2
DHW MODE
in DHW mode
7.1.3
T4_IBH_ON
The ambient temp. for starting the backup heater
The temp. difference between T1S (target outlet water temp.)
7.1.4
dT1_IBH_ON
and T1 (actual outlet water temp.) for starting the backup
heater (T1 T1S - dT1 IBH ON)
The time that the compressor has run before the first backup
7.1.5
t_IBH_DELAY
heater turn ON
The time that the compressor has run before the second backup
7.1.6
t_IBH12_DELAY
heater turn ON
7.2
AHS
The selection for whether the additional heating sourse is avalaible
The selección for whether the additional heating source will
7.2.1
HEAT MODE
be used in space heating mode
The selección for whether the additional heating source
7.2.2
DHW MODE
will be used in DHW mode
7.2.3
T4_AHS_ON
The ambient temp. for starting the AHS
The temp. difference between T1S (target outlet water temp.) and
7.2.4
dT1_AHS_ON
T1 (actual outlet water temp.) for turning the AHS ON
(T1 T1S - dT1 AHS ON)
The temp. difference between T1S (target outlet water temp.)
7.2.5
dT1_AHS_OFF
and T1 (actual outlet water temp.) for turning the AHS OFF
(T1 T1S + dT1 AHS OFF)
7.2.6
t_AHS_DELAY
The time that the compressor has runed before starting the AHS
7.3
SOLAR ENERGY
The selection for whether the solar energy kit is avalaible
8. HOLIDAY AWAY MODE SETTING
8.1
T1S_H.A_H
The target outlet water temp. for space heating
8.2
T5S_H.M_DHW
The target outlet water temp. for DHW
177
Value
Default value
Range
25
20 ~ 29
17
10 ~ 17
YES
YES/NON
NON
YES/NON
NON
YES/NON
NON
YES/NON
NON
YES/NON
YES
YES/NON
YES
YES/NON
NON
YES/NON
-5
-15 ~ 10
5
2 ~ 10
30
15 ~ 120
5
5 ~ 30
NON
YES/NON
YES
YES/NON
NON
YES/NON
-5
-15 ~ 10
5
2 ~ 10
0
-5 ~ 0
30
15 ~ 120
NON
YES/NON
25
20 ~ 25
25
15 ~ 25
Step
Unit
1
ºC
1
ºC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
ºC
1
ºC
5
min
5
min
-
-
-
-
-
-
1
ºC
1
ºC
1
ºC
5
min
-
-
1
ºC
1
ºC