Ferroli DIVACONDENS D PLUS F 24 Instrucciones De Uso, Instalación Y Mantenimiento página 41

Ocultar thumbs Ver también para DIVACONDENS D PLUS F 24:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
DIVACONDENS D PLUS F 24
Connection with separate pipes
C
5x
fig. 14 - Examples of connection with separate pipes (
Table. 4 - Typology
Type
Description
C1X
Wall horizontal exhaust and intake. The inlet/outlet terminals must be concentric or close enough to be
undergo similar wind conditions (within 50 cm)
C3X
Roof vertical exhaust and intake. Inlet/outlet terminals like for C12
C5X
Wall or roof exhaust and intake separate or in any case in areas with different pressures. The exhaust
and intake must not be positioned on opposite walls.
C6X
Intake and exhaust with separately certified pipes (EN 1856/1)
B2X
Intake from installation room and wall or roof exhaust
IMPORTANT - THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION
For the connection of separate ducts, fit the unit with the following starting accessories:
Ø 81
fig. 15 - Starting accessory for separate ducts
cod. 041039X0
cod. 390C0110
Before installation, make sure the maximum permissible length has not been exceeded
by means of a simple calculation:
1.
Establish the layout of the system of split flues, including accessories and outlet ter-
minals.
2.
Consult table 6 and identify the losses in m
nent, according to the installation position.
3.
Check that the sum total of losses is less than or equal to the maximum permissible
length in table 5.
Table. 5- Baffles for separate ducts
Max. permissible length
60 m
eq
Baffle to use
0 ÷ 20 m
20 ÷ 45 m
45 ÷ 60 m
B
C
2x
1x
= Air /
Ø 81
041039X0
(equivalent meters) of every compo-
eq
Separate ducts
Natural Gas
LPG
Ø 45
0 ÷ 30 m
eq
eq
Ø 50
30 ÷ 45 m
eq
eq
No baffle
45 ÷ 60 m
eq
eq
cod. 3541P652 - Rev. 00 - 08/2019
Table. 6 - Accessories
PIPE 1 m M/F
BEND 45° M/F
PIPE SECTION with test point
Ø 80
TERMINAL air, wall
FLUE Split air/fumes 80/80
= Fumes)
PIPE 1 m M/F
BEND 90° M/F
Ø 60
REDUCTION 80/60
TERMINAL fumes, wall with antiwind
Connection to collective flues
C
8X
C
93
fig. 16 - Examples of connection to collective flues (
Table. 7 - Typology
Type
Description
C2X
Intake and exhaust in common flue (intake and exhaust in same flue)
C4X
Intake and exhaust in common and separate flues, but undergoing similar wind conditions
C8X
Exhaust in single or common flue and wall intake
B3X
Intake from installation room by means of concentric duct (that encloses the exhaust) and exhaust in
common flue with natural draught
IMPORTANT- THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION
C93
Exhaust to a vertical terminal and intake from existing flue.
If the boiler is to be connected DIVACONDENS D PLUS F 24 to a collective flue or to a
single flue with natural draught, the flue or chimney must be expressly designed by pro-
Ø 43
fessionally qualified technical personnel in conformity with the current regulations and be
Ø 50
suitable for sealed chamber units equipped with fan.
No baffle
1KWMA83W
1KWMA65W
90° M/F
1KWMA01W
1KWMA70W
1KWMA85A
fumes, wall with antiwind
1KWMA86A
010027X0
Fume outlet only Ø80
010026X0 +
1KWMA86U
1KWMA89W
1KWMA88W
041050X0
1KWMA90A
ATTENTION: CONSIDER THE HIGH PRESSURE LOSSES OF Ø60 ACCESSORIES;
USE THEM ONLY IF NECESSARY AND AT THE LAST FUME EXHAUST SECTION.
C
2X
Losses in m
eq
Air
Fume exhaust
inlet
Vertical
Horizontal
1.0
1.6
2.0
1.2
1.8
1,5
2.0
0.3
0.3
2.0
-
-
5.0
-
12.0
-
4.0
6.0
4.5
5.0
7.0
C
4X
C
93
= Air /
= Fumes)
41
EN
Tabla de contenido
loading

Tabla de contenido