7. Twin Bio Luxury boiler design (as a complete heating device)
e. Boiler sensor installation
The boiler is fitted with a safety temperature limiter STB, pre-set to 90°C. If
the set temperature is exceeded, the STB stops the burner and the fuel feeder
operation. Alarm is displayed. Check and remove the cause for boiler
overheating. Allow the boiler to cool, remove the STB nut and press the button.
The boiler temperature sensor [3] and the STB [4] must be installed in the
boiler temperature sensor casing [7]. Sensors must be secured against falling
out.
Experts in biomass heating
CAUTION!
INCORRECT BOILER SENSOR INSTALLATION MAY RESULT IN
OVERHEATING AND FAULTY SYSTEM OPERATION.