1. Introduction | 2. General ... | 3. Scope of delivery | 4. Design guidelines
54
1. Introduction
The Twin Bio Luxury boiler with maximum power of 16, 24, 32 [kW] and
automatic pellet feeding sets new trends in utilising biological fuel. The Twin Bio
Luxury boiler can, without exaggeration, be called a 'heating system' , as this one
device constitutes the best quality, fully equipped and automated product. The
planar boiler design with water 'tongue pipes' allows for the optimal use of the
device's heating surface and does not expose the exchanger section to excessive
thermal loads while maintaining compact dimensions. Our company offers
reliable, durable and cost-effective solutions.
The device has the capability to automatically burn biomass in the form of
pellets. The simple and intuitive operation of boiler/boiler room control systems
is also important to the user. The large graphic display and the ergonomic and
clear interface of the boiler control system make our solutions easy to use.
2. General information
The operation manual is an integral part of the boiler and must be provided to
the user of this device. Install the product in accordance with this User Manual,
relevant standards and practices. Boiler operation conforming to the User
Manual guarantees safe and failure free functioning and is a precondition for
the manufacturer's warranty coverage. The specifications may change without
notice.
KOSTRZEWA IS NOT LIABLE FOR ANY DAMAGE DUE TO INCORRECT
INSTALLATION OF THE PRODUCT OR FAILURE TO OBSERVE THE
CONDITIONS SPECIFIED IN THIS USER MANUAL.
Experts in biomass heating
3. Scope of delivery
The Twin Bio Luxury boiler is provided on a wooden 1350x900 mm pallet
including:
•
palnik Platinum Bio VG
•
boiler heat exchanger with integrated controller
•
ceramic chamber
•
flexible duct, Ø 70, length 1m
•
feeder chute
•
storage hopper 290l
•
feeder chute to the storage hopper with cap
•
fuel feeder
•
ruszta żeliwne do spalania sztab drewna.
(13szt.-12kW, 16kW; 17szt.- 24kW;20szt.32kW)
•
podpórka rusztów żeliwnych
•
cleaning tool kit
•
user manual
4. Design guidelines
THE INSTALLATION AND ALL CONNECTIONS MUST COMPLY WITH
THE RELEVANT STANDARDS AND REGULATIONS!
a. Burner location requirements
The distance of boiler walls and accessories from the room walls must
guarantee easy and failure free operation of the hot water boiler (boiler control
system operation, efficient manual fuel feeding to the storage hopper, repairs,
inspections etc.). Ensure sufficient space when planning and installing the
boiler and its accessories in the distance required to open all boiler doors, clean
the combustion chamber and the exchanger baffles.
The recommended installation space for the boiler and its accessories
is shown in the Figure 6.2. Boiler location in the boiler room - dimension
diagram and Table 4. Boiler room dimension data.
Table 1. Boiler room dimension data.
Boiler room dimensions
Marking
A1
B1
C1
H1
g
Twin Bio Luxury User Manual – EN 03.17
Values
≥500mm
Dla mocy
12,16kW ≥ 700mm
Dla mocy
24kW ≥ 800mm
Dla mocy
32kW ≥ 900mm
≥500mm
≥2000mm
≥ 50mm