ELECTRICAL
Check the thermostat sequence (cooling / ventilation cooling / calefaction);
Check the alternator;
Check the tightness of the power cable on the alternator, general fuse, electric board and starter engine;
Visually inspect the alternator's belts checking tension, alignment and excessive wear out;
Clean the alternator, check for corrosion and check the electrical connections;
Check high and low speed of evaporator fan and the flow of air from the evaporator and condenser fan;
Clean the control panel area and thermostat sensor area with compressed air;
Inspect all wires and terminal regarding damages and corrosion.
Note: We recommend using this table to develop a plan of periodic maintenance to your vehicles.
IMPORTANT: The cleaning of the air return filter located in the passage of the bus and the condenser
serpentine located in the vehicle external part must be weekly carried out by the owner. Failure in carrying
out these maintenance activities may be regarded as neglectfulness resulting in the warranty
cancellation.
As a rule, the air duct cleaning must be carried out every three months, such time may be reduced in
accordance with the use of the air conditioner system, the number of people to be transported as well as
how harsh the environmental conditions are. The owners of the vehicles are entirely responsible for the
cleaning process; they will account for any cost resulting from the bad quality of air offered to their
passengers.
Preventative Maintenance
Monthly
Quarterly Annually
X
X
X
X
X
X
X
X