REBER 9340 N Manual De Uso página 99

Ocultar thumbs Ver también para 9340 N:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 112
5-
If pushing on pump switch (1), the pump start, it means the cycle was not correct, re-start
from point 1
6-
Wait 10 seconds to start working normally with new seal power set
7-
New set will remains in memory of the machine even if you disconnect the machine from
power supply.
Default sealing time is 5 time/power units
Be careful! don't set more then 9 time/power units or the teflon protection of the sealing bar
can burns
TO SET TO DEFAULT AGAIN
- Press and keep pressed the two switches- Connect the unit
TO CHANGE FROM THE AUTOMATIC TO MANUAL USE
- Disconnect the unit
- Press and keep pressed the start switch
- Connect the unit
- Wait the green led light
TO CHANGE FROM THE MANUAL TO AUTOMATIC USE
- Disconnect the unit
- Press and keep pressed the seal switch
- Connect the unit
- Wait the green led light
VACUUM PACKAGING IN BAGS
Introduce the product into a bag suitable for vacuum food preservation; leave at least 3 cm
free room from bag opening.
Lift the cover (6.) and place the bag (in well spread conditions) on the welding bar (9.), on
the left of the slide (11.). Make sure that the open side of the bag is inserted in the vacuum
chamber (8.). ( picture1 )
Introduce the cable plug into a socket and start the air pump by pressing switch (1.).
Slightly press your hands on the cover (6) to produce an initial depression in the vacuum
chamber, until the bag starts adhering to the product (pressing as long as vacuum
packaging has been completed is not necessary).
When the vacuum level is reached, the welding start automatically .
After welding the unit stops.
Cod. 9340 N – 9340 NAUS – 9340 NCSA– 9342 N (S-T-R-B): Push laterally the opening
valve of the cover (7.) to lift the cover and remove the bag.
Cod. 9346 N (F) – 9348 N (F): the opening of the cover is automatic.
Before storing the bag, check that welding has been carried out correctly. No wrinkles or
impurities capable of letting air in shall be present. (picture 4)
VACUUM PACKAGING IN ROLLS
Lift the cover (6.) and place the roll (in well spread conditions) on the welding bar (9.), on
the left of the slide (11.). Make sure that the open side of the roll is NOT inserted in the
vacuum chamber (8.). ( picture1 )
Introduce the cable plug into a socket and start the air pump by pressing switch (1.).
Slightly press your hands on the cover (6) to produce an initial depression in the vacuum
chamber.
When the vacuum level is reached, the welding start automatically .
After welding the unit stops.