English
Always remove the battery before carrying out any work on the power tool.
Condition
Running time is too short
Battery jams when being inserted in power
tool / charger
Battery is not charging even though the light
emitting diode on the charger lights up green
Light emitting diode on charger flashes red
1)
STIHL recommends a STIHL servicing dealer.
24
Cause
Battery is not fully charged
Life of battery has been reached or
exceeded
Blades sticking / dirty
Guides dirty
Battery too hot / too cold
(1 light emitting diode on battery lights
up red)
No electrical contact between charger
and battery
Battery faulty
(4 light emitting diodes on battery flash
red for about 5 seconds)
Charger faulty
Remedy
Charge the battery
1)
Check battery
and replace
Clean the blades and spray them with
STIHL resin solvent
Carefully clean the guides
Allow battery to cool down / Warm up
battery slowly at a temperature of 60°F
to 70°F (15°C–20°C).
Operate the charger only in enclosed
and dry rooms at ambient temperatures
between 40°F (5°C) and 105°F (5°C–
40°C).
Remove the battery and refit it properly
1)
Install new battery
Have charger checked by servicing
1)
dealer
HSA 65