Voltage Selection - Simer 2205C Manual Del Usuario

Bombas de chorro
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation
4
Process A. Determine
the Depth of
Your Well
Shallow
wells
are less than 25 feet to water;
deep wells
are up
to 70 feet to waten Tie a small but heavy weight
to the end of
a piece of string (be sure there is enough
string; some wells
are
very deep). J.ower the weight
into the well until it reaches the
bottom.
Take up the slack and mark the string at ground
level.
Pull the weight
out of the well and measure
from the bottom
of
the weight
to the ground
level mark. This is the depth
of your
well.
Subtract five feet from the depth
of your well. This number
should
not exceed
the maximum
rated depth
for your pump.
If
it does, it will greatly
hinder
or prevent
the proper operation
of
the pump.
Process
B. Correctly
Select Your Pump
Voltage
[_WARNING[
Hazardous
voltage.
Disconnect
power
to pump
before working
on pump
or motor.
Disconnect
pump
from
power
source before changing
the pump
voltage.
To change the
voltage,
the selector
switch
is located
underneath
the plastic
access cover on top of the motor. To access the switch,
remove
the eight screws holding
the plastic coven To change the voltage
setting,
slide the switch
as shown
until desired voltage
is visible
on the switch.
The voltage
number
that appears is the voltage
setting for the pump.
Be sure the switch
is completely
engaged.
Replace the cover and secure it with the eight screws.
VOLTAGE SELECTION
DIRECTIONS
Warning!
Disconnect pump from power
source before servicing or
handling pump.
Be sure that incoming power
supply is same as voltage
selector switch setting.
To change voltage settings
slide switch as shown
until desired voltage is
visible on switch.
Be sure switch is completely
engaged.
Replace capacitor housing cover
and secure cover with screws.
Do not overtighten screws.
Wiring
Your
Pump
Ig, WARNING]
Hazardous
voltage.
Disconnect
power
to pump
before working
on pump
or match
Disconnect
pump from
power
before servicing
or handling
pump.
Remove the cover
from the pressure switch.
Connect
the bare copper
ground
to
the ground
screw in the pressure
switch.
Connect
the power
supply
to the terminals
marked
"Line"
in the diagram
below.
Ground
Connections -_
__]_n fTo Motor
From Line
5907
1108
Piping
Plastic- PVC pipe is shown
in the illustrations,
but galvanized
steel pipe may be used if desired.
All piping
must be clean and
free of all foreign
matter to prevent
clogging.
ALL JOINTS AND
CONNECTIONS
IN THE WE[_[. ASSEMBLY MUST
BE AIRTIGHT.
Even a pinhole
leak will prevent
the proper
operation
of
the pump (this is the most common
problem).
Use thread
compound
on all threaded
joints
unless specified
otherwise.
Wiring Chart - Recommended
Wire And Fuse Sizes
Motor
Model
HP
Volts
2205C
1/2
115/230
2207C
3/4
115/230
2210C
1
115/230
3205C
1/2
115/230
3207C
3/4
115/230
3210C
1
115/230
Nameplate
Amps
8.5/4.2
1 1.0/5.5
12.0/6.0
7.0/3.5
11.0/5.5
11.0/5.5
Branch
Fuse
Rating Amp
15/15
20/15
20/15
15/15
20/15
20/15
Distance
In Feet(Meters)
From Motor
To Supply
0- 100
101 - 200
201 - 300
301 - 400
(0- 30)
(31 - 61)
(62 - 91)
(92 - 122)
AWG Wire Size (mm0
14/14(2/2)
12/14(3/2)
12/14(3/2)
14/14(2/2)
12/14(3/2)
12/14(3/2)
12/14(3/2)
10/14(5.5/2)
10/14(5.5/2)
12/14(3/2)
10/14(5.5/2)
10/14(5.5/2)
10/14(5.5/2)
8/14(8.4/2)
8/14(8.4/2)
10/14(5.5/2)
8/14(8.4/2)
8/14(8.4/2)
8/14(8.4/2)
6/14(14/2)
6/14(14/2)
10/14(5.5/2)
6/14( 14/2 )
6/14(14/2)
Tabla de contenido
loading

Este manual también es adecuado para:

2207c2210c3205c3207c3210c

Tabla de contenido