Remove cover
Only remove the cover with the heating switched off
and cold.
By simultaneously pressing both closure levers (64) outwards,
the cover is unlocked. It can be pivoted out and lifted out of
the lower bearings.
64
Function test
After installation, the tightness of the gas supply line
must be tested according to the pressure drop method.
A test certificate (according to DVGW worksheet G 607 in
Germany) is to be issued.
Version with lighting
Each time the 12 V voltage supply is produced, the sensor
electronics calibrate the lighting. This can take several sec-
onds. Do not touch the cover during calibration.
Then check all the functions of the unit in accordance with the
instructions for use.
The operating instructions must be handed to the owner of
the vehicle.
Warnings
The stickers enclosed with the unit must be attached to the
vehicle in a visible place for all users by the installer or vehicle
owner! Any missing stickers can be ordered from Truma.
20
Technical data
(established according to EN 624 or Truma test conditions)
S 3004 / S 3004 P / S 5004
Gas type
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Rated thermal output
S 3004 / S 3004 (P): 3500 W
S 5004:
6000 W
Gas consumption
S 3004 / S 3004 P: 30 – 280 g/h
S 5004:
60 – 480 g/h
Additional information according to EN 624
S 3004 / S 3004 (P): Q
= 4,0 kW (Hs); 290 g/h; C
n
S 5004:
Q
= 6,8 kW (Hs); 490 g/h; C
n
Countries of destination
BE, BG, RO, DK, DE, EE, FI, FR, GB, UK, IS, IE, IT, LV, LT, LU,
MT, NL, NO, AT, PL, PT, SE, CH, SK, SI, ES, CZ, HU, CY
Operating voltage
1.5 V (auto-igniter with battery)
Current draw
225 mW (ignite)
Weight
S 3004 / S 3004 (P): approx. 10.3 kg (without fan)
S 5004:
approx. 17.5 kg (without fan)
The right to effect technical modifications is reserved!