3.4
Installation of the safety cone
Choice of the safety guard to assemble on Bertolini pumps depends on two fundamental
factors:
1. The CE safety standards require the overlap between the pump safety guard and
that of the cardan (S) to be ≥50 mm;
2. It is essential to be familiar with the characteristics of the cardan shaft used.
The most suitable safety cone for the type of pump in question must be chosen by
considering that S (overlap) equals S=A-B (≥ 50 mm), where A indicates the projection of
the safety guards to be used on Bertolini pumps and B indicates the projection of the
cardan shaft used in the installation
PUMPS
POLY 2020-POLY 2025 VF
PA 330-430-408-508-608 VF VC
PA 530-730
PPS 100
PA/S 908-1108-1250
PA/S 124-144-154
POLY 2073/2100
POLY 2116/2136
POLY 2180
POLY 2210-2250-2260-2300
(*) RECOMMENDED SAFETY CONE
SAFETY GUARDS PROJECTION (mm)
FRONT
CODE
31.1468.32 (*)
31.1482.32
31.1468.32
31.1482.32 (*)
31.1467.32
31.1466.32
31.1466.32
31.1466.32
31.1468.32 (*)
31.1482.32
31.1482.32 (*)
31.1468.32
31.1482.32 (*)
Dimension
CODE
A
70.5
115.5
73
118
31.1468.32
106
90
31.1468.32
31.1468.32
99
31.1482.32 (*)
31.1468.32
78.5
31.1482.32 (*)
100
106.5
31.1466.32
118
31.1482.32 (*)
89
31.1468.32
134
31.1482.32 (*)
BACK
Dimension
A
68
86
83.4
128.4
96
141
88
133
78
123
62