72
5-32
5-33
5-34
Operation "MODE"
Code C8
Figure 5-32 Selecting the threshold value for sup-
pressing minor imbalances in grams or oz. The unit of
measure depends on the C3 code setting.
Ounces:
Grammes:
Range 0.25 to 2.00 oz
Range 5 to 20.0 g
Factory-adjusted to 0.25 oz
Factory-adjusted to 5 g
Read out limit, e. g. 0.25 oz
Read out limit, e. g. 5 g
Select another limit, e. g. 0.50 oz
Select another limit, e. g. 5.50 g
— Press OK.
— Press OK.
Grammes:
Ounces:
Range 3.50 to 20.0 g
Range 0.25 to 2.00 oz
Factory-adjusted to 3.5 g
Factory-adjusted to 0.25 oz
Read out limit, e. g. 3.50 g
Read out limit, e. g. 0.25 oz
Select another limit, e. g. 5.50 g
Select another limit, e. g. 0.50 oz
— Press OK.
— Press OK.
After the confi rmation OK, this operating mode can be
acquired in the permanent memory (C10).
Code C10
Figure 5-33 Saving an operating mode in the perma-
nent memory.
0*
=
Don't save
1
=
Save the data in the permanent memory.
The machine sounds a three tone beep to confi rm
•
that the data has been saved permanently.
If you have to save the operating mode permanently,
fi rst change the state, e.g. activate it, disable it and
then save it in the permanent memory using the C10
code (this does not apply to C4).
Code C13
Figure 5-34 Starting a measuring run by lowering the
wheel guard
0*
=
Start a run using the START key
=
Start a run by lowering the wheel guard
1
The operating mode selected can be obtained from
the permanent memory.
* = Preset by the manufacturer