Trouble shooting
H28 - Figure
6-10
The gauge was moved too slowly.
Return the gauge the starting position and repeat
the operation, bringing the gauge towards the weight
application point again.
H80 - Figure
6-11
Recalibration was not set up. As a result, it cannot be
performed by the operator.
Press the STOP key to clear the message.
Call the service team for machine calibration.
H82 - Figure
6-12
The self-test was disturbed (e.g.: by turning the wheel).
The message is displayed for 3 seconds, then the
measurement is repeated (max. 10 times) or aborted
by pressing the STOP key.
H90 - Figure
6-13
Wheel acceleration was too slow, or braking was too
weak after a measuring run.
If the main shaft does not reach the required speed,
check that the brake is not activated or the weight of
the wheel is too great. In this case:
Release the brake.
Make sure that the shaft with the wheel clamped on it
can rotate freely.
Turn the wheel by hand then press the START key.
If the error cannot be eliminated, call the service team.
H91 - Figure
6-14
Speed variations during measuring run. The brake
may be ON.
Release the brake.
Make sure that the shaft with the wheel clamped on it
can rotate freely.
Repeat the run.
7.2
After-sales service
7.2
After-sales service
Contact your area agent.
Contact your area agent.
The company website provides information about the
The company website provides information about the
Customer Assistance service around the world:
Customer Assistance service around the world:
https://service.snapon-equipment.net
http://www.hofmann-usa.com
http://www.hofmann.ca
Hotline (International) +49 8634 622-8996
Customer Care
Hotline (German): +49 8634 622-8994
Phone: 501-450-1500
Reception +49 8634 622-0
Fax: 501-450-2085·
· Snap-on Equipment Germany ·
· Konrad-Zuse-Straße,1 D-84579 Unterneukirchen ·