System monitoring

General

The inverter is equipped with the Wi-Fi enabled system monitoring of the Fronius Data
Manager 2.0.
The monitoring system includes the following functions:
-
-
-
-
-
-
-
-
-
Further information about the Fronius Data Manager 2.0 can be found online in the Fronius
Data Manager 2.0 operating instructions.
Starting for the
First Time via the
Fronius So-
lar.web App
To start Fronius Datamanager 2.0 for the first time,
-
-
IMPORTANT! To establish a connection to Fronius Datamanager 2.0, the end device in
question (e.g., laptop, tablet) must be configured as follows:
-
1
2
own website with display of actual data and a wide variety of settings
Connection-possibility to Fronius Solar.web via WiFi or LAN
automatic sending of service messages via SMS or e-mail in case of errors
Possibility to control the inverter by setting of power limits, minimum or maximum op-
erational times or target operational times
Controlling the inverter via Modbus (TCP / RTU)
Allocation of control priorities
Controlling the inverter by connected meters (Fronius Smart Meter)
Controlling the inverter via a ripple control signal receiver (eg reactive power setting
or power setting)
dynamic power reduction considering the self consumption
NOTE! The Fronius Solar.web App makes commissioning Fronius Datamanager
2.0 significantly easier. The Fronius Solar.web App is available in the relevant app
store.
the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
"Obtain an IP address automatically (DHCP)" must be activated
Connect the inverters with Fronius Datamanager 2.0 or Fronius Datamanager Box 2.0
in Fronius Solar Net
IMPORTANT! Inverters Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG
Plus A, Fronius CL, Fronius CL USA, and Fronius IG 300–500 must always be located
at the beginning or end of the Fronius Solar Net ring.
For Fronius Galvo/Fronius Symo/Fronius Primo only and when linking multiple invert-
ers in Fronius Solar Net:
Set the Fronius Solar Net master/slave switch on the Fronius Datamanager 2.0 plug-
in card as required
-
One inverter with Fronius Datamanager 2.0 = master
-
All other inverters with Fronius Datamanager 2.0 = slave (the LEDs on the Fro-
nius Datamanager 2.0 plug-in cards are off)