Rev. 03 - 07/2015 - Cod. 1501151 - Instruction manual for vacuum chamber packaging machines Mod. C254-C308-C312-C412-C420
5) Start the cycle.
Lower the lid, holding the bag in position.
The cycle starts automatically.
6) Sealing the bag.
Seal the bag at the desired vacuum level, which can be detected by the vacuum gauge, by pressing the
SEal key.
7) End of cycle.
The lid is opened automatically. Remove the packed product, paying attention not to touch the sealing bar,
which could still be hot.
8) Interrupting a cycle.
The machine immediately stops the cycle and the chamber is decompressed when the StOP button is
pressed at any time. The lid is opened automatically.