Frequency ranges: 50Hz ~ 1kHz. Accuracy of f: ±(0.1% rdg + 5
dgts). The readings of frequency measurements will show on the
sub-display.
Minimum Input voltage Range: >500dgts.
Overload protection: 1000V DC or 750V AC rms.
AC current (True RMS)
Range
Resolution
660A
0,1A
1500A
1A
Crest Factor: ≤3.
AC coupled true rms specified from 5% to 100% of range.
Frequency ranges: 50Hz ~ 1kHz. Accuracy: ±(0.1% rdg + 5 dgts).
The readings of frequency measurements will show on the sub-
display.
Minimum Input current Range: >500dgts.
Overload protection: 1500A AC.
DC current
Range
660A
2000A
Overload protection: 2000A DC for 60 seconds maximum.
Resistance
Range
Resolution
660Ω
0,1Ω
6,6kΩ
66kΩ
660kΩ
100Ω
6,6MΩ
66MΩ
10kΩ
38
0...660A ±(2,0% rdg + 10d) 50...60Hz
0...660A ±(3,0% rdg + 10d) 61...400Hz
660...1000A ±(2,5% rdg + 10d) 50...60Hz
660...1000A ±(3,5% rdg + 10d) 61...400Hz
1000...1500A ±(5,0% rdg + 10d) 50...400Hz
Resolution
0,1A
1A
±(1,0% rdg + 5d)
±(1,0% rdg + 5d)
1Ω
±(1,0% rdg + 5d)
10Ω
±(1,0% rdg + 5d)
±(2,0% rdg + 5d)
1kΩ
±(3,5% rdg + 5d)
CMP-2000 – USER MANUAL
Accuracy
0...660A ±(2,0% rdg + 5d)
660...1000A ±(3,0% rdg + 5d)
1000...2000A ±(5,0% rdg + 5d)
Accuracy
Accuracy
Open Circuit Voltage
-3,2V d.c.
-1,1V d.c.
-1,1V d.c.
-1,1V d.c.
-1,1V d.c.
-1,1V d.c.