Q9:
: What are the important points for O-ring maintenance?
A9:
: Pay special attention to the following items.
1 Never use alcohol, thinner, benzene or similar organic solvents or chemical detergents to
clean the O-ring. When such chemicals are used, the O-ring may be damaged or its
deterioration may be accelerated.
2 Always use genuine Olympus Silicon Grease for (in the tube with a white cap). Other grease
may not be suitable for the silicon O-rings on the Case. Using the wrong grease may result
in deterioration of the Case's surface finish and interfere with the waterproof capability.
3 In order to avoid deformation of the O-ring when the Case is not used for a long time,
remove the O-ring from the Case, apply a thin coat of the special grease, and store the O-
ring in a clean plastic bag. For reuse, confirm that the O-ring is free of damage and cracks,
that it has sufficient elasticity, that the surface is free of stickiness and other abnormalities,
and use it after applying a thin coat of the special grease. Excessive application of grease
does not improve the waterproof function or the permissible withstand pressure. However,
it may facilitate attachment of sand, dirt, etc. A thin, uniform coat produces the best result.
4 Use the provided silicon grease to apply onto the threaded portions of the Waterproof Port
and the port of the Case.
5 The O-ring is a consumable product. Replace it at least once a year. Before each use,
perform the proper maintenance.
6 Deterioration of the O-ring is accelerated by the usage conditions and the storage
conditions. Replace the O-ring immediately with a new piece if it shows signs of damage,
cracking or loss of elasticity.
Q10: : What precautions need to be taken for proper maintenance of the Case?
A10: : Pay special attention to the following items.
Do not use the following chemicals for cleaning, rust prevention, fogging prevention or repair
of the Case.
• Do not use a volatile solvent such as alcohol, lacquer thinner or benzine or a chemical
detergent to clean the Case. Fresh or lukewarm water is sufficient.
• Do not use an anti-corrosive agent to clean metallic parts. Metallic parts should be
immersed in fresh water and washed thoroughly after use. If you are concerned with the
possibility of rust, apply a thin layer of the silicone grease to the metallic parts before use.
• Do not use a commercially available anti-fogging agent. Always use the Olympus-genuine
silica gel to prevent fogging.
• Do not use an adhesive agent for repairs, etc. Please contact a service station of our
company or your dealer, if repair should be necessary.
Q11: : Please tell me about repairs.
A11
: Please contact a service station of our company or your dealer, if repair should be necessary.
Do not try to repair, disassemble or modify the Case yourself. Repair, disassembly or
En
modification by you or third parties not authorized by Olympus invalidates the guarantee.
Q12: : What are the model numbers of the accessories for the PT-E05?
A12
: The following accessories are available:
1 O-rings for the PT-E05 body (POL-E05A, POL-E05B): These are silicon rubber O-rings that
have to be installed in the PT-E05 body to make it waterproof. There are two types of O-
rings. O-rings for other Case models cannot be used.
2 The following waterproof ports are available for use with the PT-E05 Choose the one
corresponding to the lens you are using.