Beretta Mynute Boiler Green 25 B.S.I. Manual De Instalador Y Usuario página 168

Ocultar thumbs Ver también para Mynute Boiler Green 25 B.S.I.:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Mynute Boiler Green B.S.I. E
Mynute Boiler Green 25 B.S.I. E
M2
M2a
[EN] "L-N" Polarisation is recommended
Blu=Blue ● Marrone=Brown ● Nero=Black ●
Rosso=Red ● Bianco=White ● Viola=Violet ●
Grigio=Grey ● Rosa=Pink ● Arancione=Orange ●
Giallo=Yellow ● Verde=Green
A = External probe
B = Room thermostat jumper (voltage free contact
input)
C = Low temperature thermostat - generic alarm
D = Gas valve
E = Fuse 3.15A F
AKL05 GAR
Control board with digital display
integrated
P1
Potentiometer to select off - summer - winter
– reset / temperature heating
P2
Potentiometer to select domestic hot water
set point
P3
Thermoregulation curve preselection
P4
Not used
JP1 Bridge to enable knobs for calibration only
max heating (MAX_CD_ADJ)
JP2 Bridge to reset the heating timer
JP3 Enable front knobs for calibration in service
(MAX, MIN, MAX_CH, RLA)
JP4 Bridge to select internal water tank with probe
(JP4 inserted)
JP5 Bridge to select heating operation only
suitable for internal water tank (JP5 inserted)
JP6 Enable night-time compensation function and
continuous pump
JP7 Enable management of low temperature/
standard installations
JP8 Enable management of internal water tank
with probe (jumper not inserted)
CN1-CN15 Connectors (CN7 zone valve kit)
168
P.O.S.
S.B.
OPE
P.A.
1
2
-t°
2
3
1
2
rosa
1
CN9
1
7
V Lv
V Hv
CN3
2
1
4
CN10
1
C
S.R.
S.M.
T.L.A.
-t°
-t°
S.F.
-t°
12
1
CN11
S.W. Chimney sweep function, interruption of purge
cycle and calibration when enabled
E.R. Flame detection electrode
S.C. Condensate sensor
F1
Fuse 3.15A T
F
External fuse 3.15A F
M2
Terminal board for external connections: low
temperature thermostat/generic alarm
M2a Terminal board for external connections:
domestic water time programmer
M3
Terminal board for external connections: 230 V
M6
Terminal board for external connections:
Open therm/water tank probe/room thermostat
P
Pump
PWM PWM signal
OPE Gas valve operator
V Hv Fan power supply 230 V
V Lv Fan control signal
3V
3-way valve servomotor
E.A. Ignition electrode
TSC2 Ignition transformer
P.O.S. Domestic water time programmer
P.A. Water pressure switch
S.B. Water tank probe
T.L.A. Water limit thermostat
S.F. Flue gas probe
S.M. Delivery temperature sensor on primary
circuit
S.R. Return temperature sensor on primary circuit
[FR] La polarisation « L-N » est recommandée
Blu=Bleu ● Marrone=Marron ● Nero=Noir ●
Rosso=Rouge ● Bianco=Blanc ● Viola=Violet ●
Rosa=Rose ● Arancio=Orange ● Grigio=Gris ●
Giallo=Jaune ● Verde=Vert
E
230 V
D
L
N
OPE
PWM
blu (-)
P
F
marrone (+)
CN12
3
4
3
4
5
CN2
6
1
3V
CN8
1
2
3
CN4
1
3
TSC2
N
F
1 2
3
CN1
M3
OT+
B
A
-t°
M6
CN7
CN6
JP7
JP6
JP5
JP4
JP3
JP2
JP1
CN5
JP8
P4
SW1
CN13
P1
CN14
P3
AKL05 GAR
1
CN9
7
1
3.15A T
F1
CN10
4
CN2
1
CN11
12
FA2
FA1
S.C.
E.A.
E.R.
A = Sonde externe
B = Shunt thermostat d'ambiance (contact sec)
C = Thermostat basse température - alarme
générique
D = Vanne de gaz
E = Fusible 3.15A F
AKL05 GAR Panneau de commande avec écran
digital intégré
P1
Potentiomètre pour sélectionner arrêt -
été - hiver - réinitialisation / chauffage en
température
P2
Potentiomètre de sélection du point de
consigne d'eau chaude sanitaire
P3
Présélection de la courbe de thermorégulation
P4
Non utilisé
JP1
Pont pour permettre de calibrer les boutons
uniquement en chauffage maximum (MAX_
CD_ADJ)
JP2
Pont pour réinitialiser le temporisateur de
chauffage
JP3
Activation des poignées avant de réglage en
service (MAX, MIN, MAX_CH, RLA)
JP4
Pont de sélection réservoir d'eau interne
avec sonde (JP4 inséré)
JP5
Pont de sélection le mode de chauffage
uniquement adapté au réservoir d'eau
interne (JP5 inséré)
JP6
Activation de la fonction de compensation de
nuit et pompe continue
JP7
Gestion de l'activation des installations basse
température/standard
JP8
Activation de la gestion du réservoir d'eau
interne avec sonde (cavalier non inséré)
CN1-CN15 Connecteurs (kit de vanne locale CN7)
CN12
1
P2
3
CN4
1
2
CN3
1
6
1
CN1
1
Tabla de contenido
loading

Este manual también es adecuado para:

Mynute boiler green 35 b.s.i. e

Tabla de contenido