HMPL-...
S
Fasten the work load to the front plate so
that the mass centre of gravity of the work
load lies in the area of the front plate, if
possible between the guide rods.
Fitting pneumatic components
S
Make sure that the compressed air con-
nections are fitted with exhaust restric-
tors.
S
Use a 5/2-way valve (pressurized in basic
position) for controlling the HMPL-... .
S
Connect the tubing to the following con-
nections (see Fig. 17):
– A (extending; black tube connection QSM-4)
– E (retracting; silver tube connection QSM-4)
– Pneumatic port for the arresting device (only
with linear module with arresting device type
HMPL-....-KP; see separate instructions).
Fitting electric components
Using proximity switches
S
If you are using proximity switches, com-
plete the fitting as follows:
1. Remove the cover of the housing and in-
sert the proximity switches through the
hole aA (only with HMPL-...-AI).
2. Proximity switches
– Place the proximity switches in the groove
aC on the stop element (see Fig. 19) and
– adjust and fasten them in the end posi-
tions of the HMPL-... .
3. Replace and fasten the cover of the housing.
Festo HMPL-... 0005NH – English
Fig. 16
Fig. 17
aA
Fig. 18
aC
Fig. 19
27