Power Supply - HOLZMANN MASCHINEN HMS 700 Instrucciones De Servicio

Afiladora de cuchillas de cepilladora
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

13.3

Power supply

When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1. The electronic connection of the machine is designated for operation with a grounded power
socket!
2. The connector plug may not be manipulated.
3. The mains supply must be secured with 16A:
4. If the connector plug doesn't fit or if it is defect, only qualified electricians may modify or
re-new it!
5. The grounding wire should be held in green-yellow.
6. A damaged cable has to be exchanged immediately!
7. Check, whether the feeding voltage and the Hz comply to the required values of the
machine. A deviation of feeding voltage of ±5% is allowed (e.g.: a machine with working
voltage of 380V can work within a voltage bandwidth of 370 till 400V.
8. Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
9. A damaged cable must be replaced immediately
Operation is only allowed with safety switch against stray
current (RCD max. stray current of 30mA)
Plug 400V:
HOLZMANN MASCHINEN GmbH
A T T E N T I O N
N O T I C E
Remove cover:
www.holzmann-maschinen.at
5 wire with N(0)-conductor.
If 4 wire: leave off N(0)-conductor
ASSEMBLY
25
HMS 700 / HMS 1000
Tabla de contenido
loading

Este manual también es adecuado para:

Hms 1000

Tabla de contenido