Position the intermediate arm and the bar
P
Connect the operator to the control board VIVO-D201(M)
Before carrying out any gate movement, ensure there is no person or object in the radius of
action of the gate and the drive mechanisms.
See the control board instructions manual for further information.
ST1
GND
SNG1
V+
ENCODER1
P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23
P1 P2 P3
V+
Brown cable
(encoder power
supply)
GND Mesh
(encoder mass)
SNG1 Green cable
(encoder signal 1)
• Use C0 to select the number of operators: (C001: one operator, C002: two operators).
• Programme the parameter C7 for operation with encoder: C701.
• Programme the parameter C3 for the operator model (TOPO: C302).
• Check turning direction by connecting the power supply (SW1 = ON). The operators close the gate
(reset). If the gate opens instead of closing, change the turning directions (C101 or C102 for A1 and
C201 or C202 for A2).
ST2
P24 P25
ENCODER2
-FT
AUX
(Test)
24 Vdc
P4 P5 P6
P7 P8
P9 P10
P11 P12
1 Position the intermediate arm (1) in the orifices of
the motor arm (2) and of the driven arm (3).
The driven arm (3) has two orifices: the drawing
shows the orifice to be used when the opening
direction is in line with direction (A). If the opening
direction is the opposite, mount on the other hole
(always use the hole furthest from the motor axle).
2 Position the bar (4) and attach it using the screw (5).
The drawing shows the position of the support
assembly when the opening direction is in line with
direction (A). If the opening direction is the
opposite, mount on the other side.
MOTOR2
SW1
G4 G5
G6
MOTOR1
G7 G8
G1 G2
G3
G1/G4 Red cable
G2/G5 Blue cable
TOPO underground electromechanical operator
INSTALLATION
ON
OFF
G9 G10
N
L
POWER - 230V
VIVO-D201:
VIVO-D201M:
P02Y