INSTALLATION
Position the driven arm (lower) and the unlocking device
Position the upper hinge and the gate
52
Installation manual
1 Position the driven arm (lower) (1) in the pivot (2).
2 Introduce lubrication grease inside the axle-tube (A).
3 Introduce the ball (3) in the axle-tube (A).
4 Position the unlocking device (4).
1 Attach the gate (1) on the upper hinge (2) and
support it on the upper driven arm (3).
Control the alignment of the upper hinge and
the operator pivot.
Control the verticality of the gate.
2 Weld the gate (1) to the upper driven arm (3).
3 Move the gate throughout its travel, checking it
moves smoothly, without any contact or stiffness.
Should manual operation be difficult, solve
the problem before proceeding with the
installation.
4 Apply anti-corrosion protection in the un-painted
areas.