Product does not
respond to DMX
Intermittent DMX
Problems
False Sensor
Reading (Priming)
If you still experience problems after trying the
solutions presented here, contact AMPRO Technical
Support.
P. 12
Tecshow Stratus 1500 | English version
Internal problem
Wrong starting ad-
dress on the product
Wrong polarity
setting on the DMX
controller
Loose or damaged
DMX cable
Internal problem
Blue
Signal cables are not
DMX compatible
Interference with AC
or radio signals
DMX cable too long
Terminator not
connected
Air bubbles in fluid
Red
line
Red
Empty fluid tank
Send product for repair
Set the correct starting address on the prod-
uct
Change the signal polarity on the controller
Check the DMX cable entering the faulty unit
Send product for repair
Replace non-DMX cables with true DMX
cables
Keep DMX cables away from AC wires or radio
equipment
Use a shorter DMX cable or install an opti-
cally coupled DMX amplifier right before the
product with intermittent problems
Install a terminator
Fill the tank. Allow the unit to reach the
normal operating temperature and for the
blue indicator to light. Set the output to the
highest level. Power cycle the unit 1-2 times
until the fluid reaches the sensor. The blue
tank indicator light stops flashing.
Fill the tank. While the unit is operating,
pinch the fluid line between your thumb
and forefinger, and hold for 3 to 5 seconds
creating a vacuum in the system. Release the
pinched portion and allow the fluid to flow
naturally
Fill the tank. While the unit is operating;
remove but do not disconnect the fluid tank
and tilt the machine at a 45° angle.
Refill tank with the correct AMPRO® wa-
ter-based fog fluid