Westinghouse Halley Manual Del Usuario
Ocultar thumbs Ver también para Halley:

Enlaces rápidos

Owner's Manual
Manual del usuariO
Halley
(Indoor/Outdoor Damp)
Please write model number here for future reference: /
Por favor, incluya el número del modelo aquí para futura referencia:
ETL-ES-Halley (Indoor/Outdoor Damp)-WH18
Net Weight:
LBS
Peso Neto:
KGS
Tabla de contenido
loading

Resumen de contenidos para Westinghouse Halley

  • Página 1 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 Owner's Manual Manual del usuariO Halley (Indoor/Outdoor Damp) Please write model number here for future reference: / Por favor, incluya el número del modelo aquí para futura referencia: Net Weight: Peso Neto:...
  • Página 2: Safety Tips

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 safety tiPs OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED ' A CCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS' AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE.
  • Página 3: Consejos De Seguridad

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 COnsejOs de seguridad HAGA LO SIGUIENTE: LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O HERIDAS PERSONALES, MONTE EN UNA CAJA DE EMBUTIR ROTULADA “ADECUADA PARA VENTILADORES DE 35 LB (15,9 KGS ) O MENOS”...
  • Página 4: Preparing For Installation Antes De La Instalación

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 PreParing fOr installatiOn antes de la instalaCión Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble).
  • Página 5: Mounting Bracket Installation Instalación Con Soporte De Montaje

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 MOunting braCket installatiOn instalaCión COn sOPOrte de MOntaje Remove the screws from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy. Rotate the mounting bracket and remove from the canopy.
  • Página 6 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 MOunting braCket installatiOn instalaCión COn sOPOrte de MOntaje Remove receiver bracket (2) from mounting bracket (1). Insert receiver into receiver bracket (2) making sure the frequency switches are accessible. Secure receiver bracket (2) to the mounting bracket (1) using the mounting screws (3).
  • Página 7: Mounting Bracket Installation

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 MOunting braCket installatiOn instalaCión COn sOPOrte de MOntaje Raise the fan assembly and insert the hook from the mounting plate into a closed hole (1) on the canopy. This will allow for hands-free wiring. Levante el montaje del ventilador e inserte el gancho del soporte de montaje en uno de los agujeros cerrados (1) del dosel. De este modo, tendrá las dos manos libres para...
  • Página 8: Wiring Options

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 wiring OPtiOns OPCión de CableadO Bare Copper or Green Cobre Pelado o Verde Green Green Verde Verde This remote control unit is equipped with 16 code combinations to prevent possible interference from or to other remote units. The frequency switches on your receiver and transmitter have been preset at the factory.
  • Página 9 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 MOunting MOntaje Carefully lift fan from the hook on the mounting bracket, making sure not to break any wire connections. The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy, allowing the two screws to slide into the mating slots.
  • Página 10 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 seCure tO Ceiling blade installatiOn asegure el ventiladOr al teChO instalaCión de las aletas Insert the blades through the slots on the motor housing as shown, and use the provided Install two screws and star washers into the mating holes of the canopy blade screws to tighten the blades to the pre-attached blade brackets.
  • Página 11: Instalación Del Artefacto Luminoso

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 light fixture installatiOn instalaCión del artefaCtO luMinOsO Remove one screw from light kit support plate. Loosen, do not remove remaining two screws from the light kit support plate. Install light kit plate onto light kit support plate. Find the wire plugs from the light kit and from the motor and slide together. Connect the blue wire from the switch housing, to the black wire from the light kit, and the white wire from the switch housing to the white wire from the light kit.
  • Página 12 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 light fixture installatiOn instalaCión del artefaCtO luMinOsO Locate the indentations on the neck of the glass and align with the protrusions on the inside of the light kit. Lift the glass up allowing the protrusions to engage the indentations of the glass, and twist the glass clockwise to lock into place.
  • Página 13 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 reverse switCh PrOCess PrOCesO del interruPtOr de MarCh atras To reverse the direction of the blades, slide the reverse switch (located on the top of the motor housing) to the opposite side. Note: Make sure slide switch is pushed firmly to one side or the other.
  • Página 14 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 braCket Of transMitter installatiOn instalaCión del sOPOrte Para el transMisOr Mount the transmitter holder onto the wall using screws provided. Place the transmitter into the holder. Monte el soporte para el transmisor a la pared usando los tornillos incluidos. Coloque el transmisor en el soporte.
  • Página 15: Remote Control Operation

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 reMOte COntrOl OPeratiOn OPeraCión COn COntrOl reMOte remote Control Operation 1. Fan Control– press and release. The remote control operates the fan speed as follows: OFF, turns fan off; HIGH, highest fan speed; MED, medium fan speed; M.LOW, medium low fan speed; LOW, low fan speed.
  • Página 16 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 OperatiOn & Maintenance Operation Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse. Warm weather/down position - (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A. This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
  • Página 17: Operación Y Mantenimiento

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 Operación y ManteniMientO Operación Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habitación, la altura del ventilador, el número de ventiladores, etc. El conmutador de tipo deslizante controla la dirección, hacia adelante o hacia atrás.
  • Página 18: Troubleshooting Guide

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these trOubleshOOting guide installation errors may be mistaken for defects. If you experience any faults, please check this troubleshooting chart. If a problem cannot be remedied, please consult with a qualified electrician and do not attempt any electrical repairs yourself.
  • Página 19: Guía Para Solucionar Problemas

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 Si tiene dificultades para hacer funcionar su nuevo ventilador, podría ser a causa del armado, instalación o cableado incorrectos. En algunos guía Para sOluCiOnar PrObleMas casos, estos errores de instalación podrían ser confundidos con defectos. Si experienca algun fallo, consulte esta guía para solucionar problemas.
  • Página 20: Parts List Lista De Repuestos

    ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 Parts list lista de rePuestOs description 1 ......... Mounting Bracket 2 ......... Blade 3 ......... Glass 4 ......... Remote Control 5 ......... Capacitor 6 ......... Hardware Pack descripción 1 ......... Soporte de montaje 2 ......... Aleta 3 ......... Pantalla de vidrio 4 .........
  • Página 21 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18...
  • Página 22 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18...
  • Página 23 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18...
  • Página 24 ETL-ES-Halley (Indoor/Outdoor Damp)-WH18 Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A. www.westinghouselighting.com , WESTINGHOUSE, and INNOVATION YOU CAN BE SURE OF are trademarks of Westinghouse Electric Corporation Used under license by Westinghouse Lighting All rights reserved. Made in China...

Este manual también es adecuado para:

7217800

Tabla de contenido