Battery Pack temperature is too hot
or too cold
(Red light flashes slowly)
Battery Pack malfunction
(Red and Green lights stay illuminated)
Warning!
1. Charger is plugged into a 100-240V
a.c outlet only.
2. If the battery pack is too hot or too
cold, the charger will not fast
charge the battery pack and the red
Indicator light is "blinking". When the battery pack
temperature returns to between 0ºC(32ºF) and
50ºC(122ºF), The charger will automatically begin
charging.
3. If both red and green indicator lights are "ON"
the battery pack either does not comply or is
defective. Please contact your retailer.
4. Do not charge the battery pack in the rain, snow
or high temperature environment.
5. Do not charge battery pack when
environment temperature is below 0ºC(32ºF)or
above 40ºC(104ºF)
6. While charge the cool battery pack (below 0 C)
in the warm indoor, keep the battery pack in the
room for one hour to warm up before starting the
battery pack.
A cool battery may charge unsaturated.
7. Remove the plug after finishing the charge.
8. Do not use generator for charging the battery
pack.
TOOL OPERATION
Cartridge Loading
1. Draw back plunger handle fully until the groove
of piston rod is latched into the slot on the
tube cap. See Fig.1.
2. Unscrew the grease container from the gun.
3. Slowly release the plunger handle to eject the
empty cartridge from the container tube.
Visually check the direction of plunger lip.
See Fig.2. Draw back plunger handle fully until
the groove of piston rod is latched into the
slot on thetube cap.
This description is not applicable for new
grease gun
4. Remove the cover from new grease cartridge and
insert cartridge into the container tube . Then
remove the pull tab. See Fig.3
5. Screw grease container ass'y into grease gun.
6. Release the piston rod from slot and push it all the
way in.
7. This gun is ready to use. If your gun fails to work, it
is due to air pocket in the grease container ass'y.
To remove the air, procedure as following
Remove Air Pocket
1. Continue to hold trigger switch meanwhile press/
release air vent valve until trapped air is removed.
2. If the gun still fails to work. Draw back the piston
rod fully and Engaging it with
plunger by rotating the plunger handle about 1/4 ~
1/2 turns to set the position of key. See Fig.4
3. Press/release air vent valve several times to relea-
se the air when push plunger handle.
4. Repeat item 1. procedure until trapped air is
removed.
5. Disengaging the plunger by rotating the plunger
handle about 1/4 ~ 1/2 turns. Push plunger rod all
the way in.
15