GE PVM1790 Instrucciones De Instalación página 17

Horno para colocar encima de la estufa
Ocultar thumbs Ver también para PVM1790:
Idiomas disponibles

Idiomas disponibles

Installation Instructions
Roll the blower unit 90° so that fan blade openings
are facing out the back of the oven.
After Rolling
Before Rolling
6 | Locate the two "knockout" plates, on the rear oven
panel, near the top of the oven.
Using tin snips, carefully cut the web area from the
two holes side-by-side (that secure the knockouts to
the oven}. Cut all four webs on both rear knockouts;
this will allow the ventilation fan airflow to exhaust
out the rear of the oven.
ACAUTION:
Be sure to trim the sharp
edges from the openings after removing the
knockout plates.
Oven Rear Panel
Snip all 4 webs
on each knockout
panel and remove
the metal knockouts
for rear airflow.
Place the blower unit back into the opening.
AFIER: Fan Blade
Openings Facing
Back
ACAUTION:
Do not pull or stretch
the blower unit wiring. Make sure the wires
are not pinched.
NOTE: The blower unit exhaust openings should
match exhaust openings on rear of oven.
17
Replace the blower plate in the same position
as before with the screws.
2
P l a t e
§
ower
Flate
screws
Y
"
Blower Plate
fA
<a
oe
Back of Oven
| 9| Insert the tabs on each side of the damper
into the holes at the inside rear of the adaptor.
Exhaust
Adaptor
Attach the exhaust adaptor to the rear of the oven
by sliding it into the guides at the top center of the
back of the oven.
Damper
=
(hinge side up)
Slide exhaust
:
adaptor into
"y
guides on
ZA eo) U7 ee
Screws
oven rear.
,
«=|
Back of Oven
Lng
Locking
.
Tabs
Guides
Push in securely until it is in the lower locking tabs.
Take care to assure the damper hinge is installed
so that it is at the top and that the damper swings
freely.
Secure the exhaust adaptor to the oven with
the two bronze metal screws provided.
loading

Este manual también es adecuado para:

Psa1200Psa2200Psa1200rww01Psa2200rww02Psa2201rss01