Lithium-Ion Battery Information
• The battery should always be removed from the Ronin before storage or
extended periods of non-use. Failure to comply could result in degradation of
the battery cells or loss of all battery life.
• The battery must be removed from the Ronin TL, before charging.
• Each Ronin battery has an over current safety cutoff to prevent lifts over max
safe working load.
• For shipping, the battery falls under UN3481 PI 966 Section II, Batteries shipped
with equipment. Due to the weight and size of the battery you can only ship
one battery per package. Contact Ronin for the Battery Safety Data Sheet.
• Stop use if battery becomes too hot to touch, or battery becomes
swollen/bloated.
• The battery should never be connected to the Ronin TL in areas with poor
ventilation or where gas may be present.
• Battery should be stored at 80% full charge and checked every 3 months to ensure the battery cells do not be
come damaged from holding a full charge. Battery needs to be stored in a cool dry place when not in use.
Type
Lithium-Ion
Voltage
48 VDC Nominal
Amperage
45amps
Battery Capacity
3.0Ah
Battery Life
Approximately 300 Charges
Operating Temperature
-4º F –140º F (-20º C –60º C)
Mass
Approximately 5.3lbs. (3Kg)
Charge Time
Approximately 2 hours
Charging Temp
95º F (35º C) Maximum
Storage Temperature
-4º F –113º F (-20º C –45º C) Less than 1 month (-4º F –95º F (-20º C –35º C) Less than 6 months)
Storage Humidity
≤ 85% Less than 1 month (≤ 70% Less than 6 months)
Storage Voltage
60 ± 20% charge approx. is recommended for extended periods of battery storage
• The battery charger is adaptable from 100v – 240v outlets.
The charger cables shipped with the unit fit type A, B or C.
• Do not leave any battery charging unattended for longer than
3–4-hours.
• Do not handle damaged or leaking lithium-ion batteries.
• Do not allow the battery to come into contact with fire or
subject to extreme temperatures such as direct sun
light for extended periods of time.
• Regularly inspect AC power cord for damage.
• After use, wait 30 minutes before charging the battery.
• After fully charging the battery wait 30 minutes before use.
Power Supply Charging
Standby (Solid Green with no battery plugged in)
Charging (Solid Red when battery is charging)
Fully Charged (Solid Green with battery plugged in)
PRODUCT SAFETY
Specifications
POWER SUPPLY INFORMATION
Specifications
Type
Lithium-Ion Battery Charger
Input Charging Voltage
100 VAC –240 VAC
Input Charging Amperage
2amps
Operating Temperature
32º F –104º F (0º C –40º C)
Operating Humidity
20% -90%
Charge Time
Approximately 2 hours
Charging Temp
104º F (40º C) Maximum
Storage Temperature
-4º F –176º F (-20º C –80º C)
Storage Humidity
0% -95%
RONINPOWERASCENDER.COM
3
|