The relay terminal block provides digital outputs to control external equipment, such as circulator pumps, fans or open/closed
valves. Each relay should be powered externally with the operating voltage of the component to be controlled. Power is supplied to
each relay separately, so different operating voltages can be used in each. The following figure shows an example of an installation
of a relay power supply.
Each relay allows independent pole switching; it can thus control the switching on/off of the units, including those powered with a
different voltage. The capacity of the relays is 8A/250Vac per pole. If the equipment to be controlled exceeds this capacity, an
external relay or contactor must be installed. Shown below are examples of connections between circulator pumps and 3-way
valves with controls at 2 or 3 points.
Pay special attention to the maximum consumption allowed by each relay. Use an intermediate relay
or a contactor for the connection, if necessary.
NOTE
L
NC: 22/12
COM: 21/11
NO: 24/14
DOxx
NC
COM
NO
A2/A1

4.2. Power supply

The e-source manager only requires one electrical connection. The power supply to the 24Vac transformer connects to it to power
the controller and other devices with low power consumption. The following table shows the characteristics of the necessary
electrical connection:
L
NC: 22/12
COM: 21/11
NO: 24/14
DOxx
NC
COM
NO
A2/A1
Figure 4.8. Example of digital output relay power supply connections.
2P
3P
L
L
on
off
NC: 22/12
COM: 21/11
NO: 24/14
DOxx
NC
COM
NO
A2/A1
Figure 4.9. Example of digital output connections.
ecoSMART e-source
user, installer and technical service manual
Control Power
Supply 230V
L1 L2/N PE
DO1
DO2
DO3
DO4
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
pLAN
BMS2
FBus
AI1
AI2
AI3
AI4
AI5
AI6
AI7
AI8
24 Vac
Control Power
Supply 230V
DO1
DO2
DO3
DO4
L1 L2/N PE
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
pLAN
BMS2
FBus
AI1
AI2
AI3
AI4
AI5
AI6
AI7
AI8
24 Vac
48
DO5
DO6
DO7
DO8
DO9
DO10
DO11
DO12
DO13
NC
NC
NC
NC
NC
NC
NC
NC
NC
COM
COM
COM
COM
COM
COM
COM
COM
COM
NO
NO
NO
NO
NO
NO
NO
NO
NO
AI9
AI10
AI11
AI12
AO1
AO2
AO3
AO4
AO5
DI1
DI2
DI3
DI4
DI5
DI6
DI7 DI8
DO5
DO6
DO7
DO8
DO9
DO10
DO11
DO12
DO13
NC
NC
NC
NC
NC
NC
NC
NC
NC
COM
COM
COM
COM
COM
COM
COM
COM
COM
NO
NO
NO
NO
NO
NO
NO
NO
NO
AI9
AI10
AI11
AI12
AO1
AO2
AO3
AO4
AO5
DI1
DI2
DI3
DI4
DI5
DI6
DI7 DI8
Tabla de contenido
loading

Tabla de contenido